Error Code Continuous OFF
High

American Standard AUH1B080A9H31A Error Code Continuous OFF: Check Power

TL;DR
Your furnace's LED is completely dark because the control board has no power. Check the circuit breaker, the furnace power switch, and the board fuse to restore power.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code Continuous OFF Mean?

When the diagnostic LED on your American Standard AUH1B080A9H31A is completely dark, the White-Rodgers 50A65 Integrated Furnace Control (IFC) is receiving no power at all. Without power the board cannot run the furnace in any mode or even display another flash code, so a dark LED is the board's way of telling you to check its power supply first.

This is one of the more approachable conditions because the cause is almost always outside the furnace. The most common reason is a tripped circuit breaker at the electrical panel, followed by the furnace's own power switch being turned off — it often looks like an ordinary wall light switch near the unit and is easy to flip by accident. A blown low-amp fuse on the IFC board (tripped by a wiring short or power surge) is a third possibility.

It is worth noting how this differs from a solid, non-blinking LED: a dark LED means no power is reaching a healthy board, while a steady light means the board has power but has failed internally and needs replacement. A dark LED is the condition most likely to be fixable by a homeowner, and because there is no power, there is no active hazard from the furnace itself while you check the breaker and switch.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Tripped circuit breaker or blown fuse Most common ✓ DIY fix →
Furnace power switch turned off Common ✓ DIY fix →

How to Fix It: Restore Power to the Furnace

⚠ Safety First
Always turn off the furnace at the power switch or breaker and shut off the gas supply before beginning. Do not proceed if you smell gas — leave the area and call your gas company immediately.

What You'll Need

Steps

  1. Turn off the furnace power switch and shut off the gas supply before inspecting For safety before you work, set the furnace power switch (and the HVAC breaker) to OFF, and turn the gas supply valve to the OFF position (handle perpendicular to the pipe). If you smell gas at any point, leave your home immediately and call your gas company from outside.
  2. Check the circuit breaker at the electrical panel Find the breaker labeled for the furnace or HVAC system. A tripped breaker sits in the middle position between ON and OFF. Reset it by pushing it firmly to OFF first, then flipping it fully to ON. If the breaker trips again immediately, stop and call a professional — a repeated trip signals an electrical fault that is not safe to reset repeatedly.
  3. Confirm the furnace power switch is on Look for a standard-looking light switch on the wall near the furnace or on the furnace cabinet itself. It is often mistaken for a room light switch and left off. Set it to ON.
  4. Inspect the control board fuse (if visible) With the panel off and power still down, look on the IFC for a small automotive-style blade fuse (commonly 3 or 5 amp). If it is visibly blown, that points to a wiring short or surge; you can replace it with an identical-rating fuse, but if it blows again, a technician should find the short rather than you continuing to replace fuses.
  5. Restore gas supply, then power Reinstall the access panel, turn the gas supply valve back to ON (handle parallel to the pipe), then set the furnace power switch and breaker back to ON. Wait a moment for the board to initialize.
  6. Verify the LED status Look through the viewing window. After power is restored you should see a slow flash, which is normal standby.
How to Verify
Once power is restored the diagnostic LED should begin a slow flash (standby). Set the thermostat to call for heat and confirm the LED switches to a fast flash and the furnace produces warm air within a few minutes.

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

Why is there no light at all on my American Standard AUH1B080A9H31A furnace?

A completely dark diagnostic LED means the control board has lost power. Start with the HVAC circuit breaker and the furnace power switch, since a tripped breaker or an off switch is the usual cause.

What is the difference between no light and a solid light on the board?

No light means the board has no power, which you can often fix by restoring the breaker or switch. A solid, steady light means the board has power but has failed internally and needs a technician to replace it.

The breaker keeps tripping when I reset it — what should I do?

Stop resetting it and call a technician. A breaker that trips immediately and repeatedly indicates a short or overload that is unsafe to keep re-energizing.

Sources

  1. Installer's Guide - Upflow/Horizontal, Downflow/Horizontal, Gas-Fired, Direct Vent Condensing Furnaces
  2. U.S. Department of Energy - Furnaces and Boilers

✓ Verified against manufacturer service manual — March 2026