Error Code 10 Red Flashes
High

York TM9T100C16MP11 Error Code 10 Red Flashes: Gas Valve Energized Without Call for Heat

TL;DR
Ten red flashes on your York TM9T100C16MP11 means the gas valve is being energized when there is no call for heat. As a safety response the blowers run and ignition is blocked. The gas valve or its wiring is likely faulty and needs a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 10 Red Flashes Mean?

A 10 red flashes code on the York TM9T100C16MP11 means the board has detected that the gas valve is receiving power without a thermostat call for heat. The valve should only be energized during an active heating cycle, so the board treats this as a safety hazard: it runs the main blower and inducer to ventilate the furnace and refuses to start any ignition sequence while the condition exists.

The most common cause is a faulty gas valve with an internal short or stuck solenoid that draws power through an unintended path, or damaged gas-valve wiring that creates a circuit energizing the valve outside the board's normal command. In either case the valve could open when it should not, allowing gas to flow without controlled ignition.

It is important to tell this apart from the 1 red flash code. Ten red flashes means the gas valve is being electrically energized without a call for heat, while 1 red flash means the sensor actually detected a flame without a call for heat. Both are gas-safety codes, but they identify different failures.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Faulty gas valve Most common ✗ Call a pro →
Faulty gas valve wiring Common ✗ Call a pro →

How This Is Diagnosed

A technician checks the gas valve coil and its wiring for a short or a stuck-energized condition, inspects the board's valve-drive circuit, and confirms the valve de-energizes and fully closes when it should. Because every likely cause involves the gas valve or its wiring, this is diagnosis and repair for a professional, not a homeowner task.

When to Call a Professional

This code involves components that are not homeowner-serviceable, so have a licensed HVAC technician diagnose and repair it. Keep in mind:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

What is the difference between 10 red flashes and 1 red flash?

Ten red flashes means the gas valve is being energized without a call for heat (an electrical fault), while 1 red flash means an actual flame was sensed without a call for heat.

Is it safe to keep running the furnace?

No. Turn the furnace off at the breaker and call a technician. If you smell gas, leave immediately and call your gas company from outside.

Can I fix a 10 red flashes code myself?

No. Gas valve and gas-valve wiring diagnosis is a safety-critical job for a qualified technician.

Sources

  1. York TM9T Technical Manual (444559-YTG-F-0615)
  2. Installation Manual - Residential Gas Furnace Models TM9T*MP (96% AFUE Two Stage Multi-position)

✓ Verified against manufacturer service manual — March 2026