Error Code Rollout Switch Open
York TM9V080B12MP11 Error Code Rollout Switch Open: Rollout Switch Open
TL;DR
The limit circuit is open for more than fifteen minutes, usually indicating that a manual-reset rollout switch has opened. Check for proper combustion air, proper inducer operation, and primary heat exchanger failure or burner problem. The control will enter a hard lockout and power will have to be cycled off and on to reset the control after the problem has been corrected. Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk. What Does Code Rollout Switch Open Mean?
The limit circuit is open for more than fifteen minutes, usually indicating that a manual-reset rollout switch has opened. Check for proper combustion air, proper inducer operation, and primary heat exchanger failure or burner problem. The control will enter a hard lockout and power will have to be cycled off and on to reset the control after the problem has been corrected.
When to Call a Professional
Contact a licensed HVAC technician if:
- Basic troubleshooting did not resolve the error
- You smell gas at any point during the process
- You are not comfortable working around gas lines or electrical components
- The unit needs a gas valve, control board, or motor replacement