Error Code EC5
Low

Amana AMVC960803BN Error Code EC5: Accessory Relay Module Missing

TL;DR
EC5 means the furnace expected to find an external accessory relay module — used to control accessories such as a humidifier or ventilator — but did not detect it. Heating usually continues, while the accessory that module switches is not managed.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EC5 Mean?

The communicating Amana AMVC960803BN can be configured to work with an external accessory relay module. This module provides the relay contacts the system uses to switch comfort accessories such as a whole-home humidifier or a ventilator, and the integrated control module expects to see it on the ComfortNet system when the configuration calls for one. Code EC5 is raised when that expected accessory relay module is not detected.

Amana rates EC5 low severity because it is an informational configuration alarm rather than a combustion or gas-safety fault. The furnace itself typically keeps heating, but the accessory the missing relay module was supposed to switch cannot be commanded while the alarm is active.

EC5 is the companion of EC4. EC5 is the accessory relay module (for accessories like a humidifier or ventilator); EC4 is the equipment relay module (for major equipment like a heat pump or air conditioner). Both are "expected module not detected" alarms. They differ in kind from EC1, EC2, and EC3, which are lost-communication alarms for the ComfortNet thermostat/network, the external E-Module, and the Bluetooth phone-app module respectively — those describe a device that was communicating and dropped out, whereas EC5 means the expected module was never found.

Because EC5 is about a module the system was told to expect, it commonly traces back to an accessory relay module that is not installed, not connected, or has failed, or to a configuration that expects a module the system does not actually have.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Accessory relay module not installed or disconnected Most common ✗ Call a pro →
Faulty accessory relay module Common ✗ Call a pro →

How This Is Diagnosed

A technician first confirms whether an accessory relay module is actually supposed to be present for this installation, then checks that the module is installed, seated, and connected on the ComfortNet system. The wiring to the module and to the accessory it drives is inspected for loose or damaged connections, since a module that is present but not properly connected will not be detected.

If a module should exist but cannot be found, the technician determines whether it needs to be installed or replaced; if no such module belongs on the system, the configuration is corrected so the control no longer expects one. This is diagnostic context only, not a homeowner repair procedure.

When to Call a Professional

This code involves components that are not homeowner-serviceable, so have a licensed HVAC technician diagnose and repair it. Keep in mind:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

Will my furnace still heat with an EC5 code?

Usually yes — the furnace continues to heat normally. What is affected is the accessory the missing relay module was supposed to switch, such as a humidifier or ventilator.

What does the accessory relay module do?

It gives the ComfortNet system the relay contacts to switch comfort accessories like a humidifier or ventilator. EC5 means the system expected this module but could not detect it.

How is EC5 different from EC4?

Both are 'expected module not detected' alarms, but EC5 is the accessory relay module for accessories like a humidifier or ventilator, while EC4 is the equipment relay module for major equipment like a heat pump or air conditioner.

Sources

  1. Service Instructions - 34.5" Chassis ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA Gas Furnaces
  2. Amana AMVC960803BN Product Page

✓ Verified against manufacturer service manual — March 2026