Goodman GMSS960803BN Furnace Error Codes

Single Stage Gas Furnace | Control Board: Integrated Control Module

Not your model? View all Goodman models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
NO LED Control failure or no power High ✗ Call a pro →
STEADY ON Normal operation Info — →
1 FLASH System lockout High ✗ Call a pro →
2 FLASHES Pressure switch stuck closed High ✗ Call a pro →
3 FLASHES Pressure switch stuck open High ✗ Call a pro →
4 FLASHES Open limit switch High ✓ Yes →
5 FLASHES Flame sensed when no flame should be present (no call for heat) Critical ✗ Call a pro →
6 FLASHES Open rollout switch or open control board fuse Critical ✗ Call a pro →
7 FLASHES Low flame sense signal Medium ✗ Call a pro →
8 FLASHES Igniter relay fault High ✗ Call a pro →
CONTINUOUS FLASH 115 Volt AC power polarity reversed High ✗ Call a pro →

How to Read the Error Code

Single diagnostic LED visible through observation window in blower access door. LED flashes a specific number of times, then pauses, and repeats. Count the number of flashes between pauses to identify the fault code. The 96% models also support Fault Recall: press the FAULT RECALL switch for ~2 seconds to display the last five stored fault codes.

About This Model

The Goodman GMSS960803BN is a single stage gas furnace using the Integrated Control Module-series integrated furnace control (IFC) board.