Error Code A
Info

Lennox SLP98UHV Error Code A: Indoor Blower CFM Setting

TL;DR
Your Lennox SLP98UHV is displaying the indoor blower CFM (airflow speed) setting. This is a diagnostic readout, not an error code.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A Mean?

The letter A in the SureLight control's menu is the indoor blower CFM (cubic feet per minute) readout. It appears when someone presses and cycles the diagnostic push button on the control board, and the LED alternates between the letter A and the current airflow value, roughly one second on and half a second off.

This is a technician's readout rather than a fault. On a modulating furnace like the SLP98UHV, airflow is matched to the firing rate to keep the temperature rise across the heat exchanger correct, so the board stores separate CFM settings for heating, cooling, and continuous fan. The A item lets an installer confirm the blower is moving the intended amount of air through your ductwork.

No action is required. Once the diagnostic menu times out, the display leaves the A item and returns to normal operation or the idle decimal. If you did not press the diagnostic button, someone else may have accessed the menu or the button may be sticking.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Diagnostic push button pressed to view blower CFM settings Most common

How This Is Diagnosed

Confirm this is a readout and not a fault by noting it only shows while the diagnostic push button is being cycled. Stop pressing the button and let the menu time out — each item advances every five seconds — and the display will move past the A entry back to the normal operating or idle indication, showing nothing is wrong.

Contact a licensed HVAC technician if any of these apply:

Frequently Asked Questions

What does the letter A mean on my Lennox SLP98UHV?

A is the diagnostic readout for the indoor blower's airflow in cubic feet per minute (CFM). It is information a technician pulls up with the diagnostic button, not an error.

Did I break something by pressing the diagnostic button?

No. Cycling the diagnostic menu only displays settings; it does not change how the furnace runs. The A readout clears on its own once the menu times out.

Why does the CFM number differ between modes?

The SLP98UHV uses different blower speeds for heating, cooling, and continuous fan, so the CFM value shown depends on which mode's setting is being displayed.