Lennox SLP98UHV Error Code E 407: LSOM - Compressor Open Run Circuit

TL;DR
Your Lennox SLP98UHV's compressor monitor detected an open run circuit at the outdoor compressor, so it cannot keep running. This is an outdoor-unit fault reported by the furnace board and needs a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 407 Mean?

Through its LSOM (Lennox System Operation Monitor), the Lennox SLP98UHV control watches the outdoor compressor and shows faults on the furnace display. E 407 means the monitor found an open run circuit — the run winding or its path is not completing, so the compressor cannot sustain operation even if it manages to start.

This is commonly caused by a failed run winding inside the compressor or by the compressor's internal thermal protection opening after it has overheated. When the run circuit is open, the compressor may hum, start briefly and drop out, or not run at all.

E 407 is part of the LSOM compressor winding-and-electrical group. It is the run-side counterpart to E 406 (an open start circuit) and falls under the broader E 405 (a compressor open circuit). It differs from E 404, which is a mechanically locked rotor. A technician distinguishes an overheated compressor that can recover from a permanently open run winding through electrical testing after the compressor cools.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Compressor run winding failure or internal thermal protection tripped Most common ✗ Call a pro →

How This Is Diagnosed

A technician confirms the unit has power, is set to cool, and is clear of debris — checks a homeowner can safely make. The electrical testing on the outdoor unit is the pro's responsibility.

Because overheating can open the run circuit through the internal protector, they let the compressor cool and recheck it. They then measure the run winding for continuity and verify refrigerant pressures and the outdoor fan. An open run winding after the compressor is cool indicates internal compressor failure and replacement; an overheating cause is corrected instead.

When to Call a Professional

This code involves components that are not homeowner-serviceable, so have a licensed HVAC technician diagnose and repair it. Keep in mind:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

Why does my Lennox SLP98UHV compressor start then stop right away?

E 407 means the run circuit is open, so the compressor cannot sustain operation. It may start on the start winding but drop out because the run winding path is not completing.

Is E 407 fixable without replacing the compressor?

Sometimes. If the compressor merely overheated and tripped its internal protector, fixing the overheating cause can restore it. A permanently open run winding, however, means the compressor must be replaced.

How is E 407 different from E 406?

E 406 is an open start circuit (the compressor struggles to begin turning), while E 407 is an open run circuit (it cannot keep running). Both are LSOM compressor faults a technician tests for.