Error Code 46
High

Ruud U96VA0702317MSA Error Code 46: Low Pressure Switch Open, Inducer on Low Speed

TL;DR
Code 46 means the Ruud U96VA lost low-stage draft — the low-pressure switch opened while the inducer ran at low speed after switching to low fire. Common causes are vent restriction or a missing high-altitude kit.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 46 Mean?

Code 46 on the Ruud U96VA0702317MSA is specific to two-stage operation. This furnace always ignites at high fire, then can step down to low-stage heating. Code 46 means that after it dropped to low stage — with the inducer at low speed — the low-pressure switch opened, so the required draft was not maintained. Because of that startup logic, this fault only appears after a successful high-fire light-off and the switch to low stage.

This is a critical fault. When it occurs, the gas valve is de-energized and the furnace attempts to restart after completing post-purge and blower off-delay. It is the low-speed sibling of code 45 (low-pressure switch open at high inducer speed) on the same switch.

Common causes include vent blockage or improper termination, vent length or elbows beyond the maximum, a faulty or disconnected inducer, split pressure-switch hoses, a faulty switch, and — notably for low-fire draft — a missing high-altitude kit at elevated installations, where thinner air makes low-speed draft marginal. This is a technician diagnosis.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Vent blockage or improper termination Most common ✗ Call a pro →
High altitude installation without proper kit Common ✗ Call a pro →

How This Is Diagnosed

A technician confirms the fault occurs at the transition to low stage, then inspects the venting for blockage and proper termination and checks that length and elbow counts are within spec, since vent restriction is the most common cause.

For elevated installations they check whether the required high-altitude kit is installed, because reduced air density can leave low-speed draft too weak; they also check the inducer, hoses, and pressure switch, replacing whatever is at fault.

When to Call a Professional

This code involves components that are not homeowner-serviceable, so have a licensed HVAC technician diagnose and repair it. Keep in mind:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

Why does code 46 only show up on low fire?

This furnace ignites at high fire and then steps down to low stage; code 46 is the low-pressure switch opening at the lower inducer speed, so it only appears after the switch to low-stage heating.

Could my altitude cause code 46?

Yes — at higher elevations thinner air weakens low-speed draft, so a missing high-altitude kit is a recognized cause and a technician can confirm whether the correct kit is needed.

Sources

  1. Installation Instructions for (-)96V Series & (-)(-)96MDV Series

✓ Verified against manufacturer service manual — March 2026