Error Code 23
Low

Bryant 355MAV Error Code 23: Pressure Switch Did Not Open

TL;DR
Your Bryant 355MAV detected that a pressure switch did not open when it should have. The pressure tubing is likely obstructed or the switch is stuck closed, which a technician needs to check.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 23 Mean?

Status code 23 on the Bryant 355MAV means a pressure switch failed to open when the control board expected it to. The pressure switch should open when the inducer stops and draft ceases; if it stays closed, the board cannot confirm the venting system is behaving correctly between cycles.

The most common cause is obstructed pressure tubing. The small hose linking the pressure switch to the inducer housing can be blocked by condensate, debris, or insect nests. Because the 355MAV is a condensing furnace, moisture in that tubing is a realistic culprit. With the hose plugged, the switch cannot sense true draft pressure and may hold its previous position.

A pressure switch stuck closed is the other likely cause — its diaphragm can stiffen or its contacts can stick so the switch will not open on demand. This is different from codes 31 and 32, where a pressure switch fails to CLOSE (or reopens) during a heat call; code 23 is specifically a switch that will not OPEN when draft stops. Diagnosis involves testing the switch and clearing the tubing, which is technician work.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Obstructed pressure tubing Most common ✗ Call a pro →
Pressure switch stuck closed Common ✗ Call a pro →

How This Is Diagnosed

A technician disconnects the pressure switch hose and confirms whether the contacts open when draft is removed; a switch that stays closed with the hose off is faulty and replaced. If the switch itself is fine, the pressure tubing and its port on the inducer housing are inspected and cleared of condensate or debris.

Because the 355MAV is a condensing furnace, the technician also looks for moisture that could migrate into the tubing. These checks require accessing the inducer and switch assembly, so they are performed by a qualified technician rather than the homeowner.

When to Call a Professional

This code involves components that are not homeowner-serviceable, so have a licensed HVAC technician diagnose and repair it. Keep in mind:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

What does code 23 mean on a Bryant 355MAV?

It means a pressure switch did not open when the inducer stopped and draft ceased. The usual causes are obstructed pressure tubing or a switch stuck in the closed position, both of which a technician should check.

How is code 23 different from codes 31 and 32?

Code 23 is a switch that fails to OPEN when it should. Codes 31 and 32 are pressure switches that fail to CLOSE (or that reopen) during a high-heat or low-heat call. They are opposite conditions on the same type of safety switch.

Sources

  1. Bryant 355MAV Troubleshooting Manual (Series H & I Variable Speed, Two-Stage Electronic Condensing Gas Furnace)
  2. Bryant 355MAV Series I Installation, Start-up, and Operating Instructions

✓ Verified against manufacturer service manual — March 2026