Error Code T117_F
Low

Rheem R802VA07542117MSA Error Code T117_F: Detect RPM Motor Failure

TL;DR
Code T117_F means the Bluetooth Communicating IFC on your Rheem R802VA07542117MSA sees the blower motor turning, but not at the RPM it was commanded to hold. It is a troubleshooting-level fault usually caused by motor bearing wear, a failing ECM module, or a dirty blower wheel, and it needs a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code T117_F Mean?

Your Rheem R802VA07542117MSA uses a variable-speed, constant-CFM/PWM blower. The Bluetooth Communicating IFC sends the ECM (electronically commutated motor) a target speed and continuously reads back the RPM the motor actually reports. Code T117_F is set when that feedback RPM does not match the commanded value closely enough — the motor is running, but at the wrong speed. This is different from a motor that cannot run at all.

The "T" prefix marks this as a troubleshooting-level fault, meaning the board observed the RPM mismatch but has not latched a lockout. It still matters, because on a constant-CFM design the whole point of the variable-speed motor is to deliver the exact airflow the furnace was engineered for. When the motor drifts off its commanded RPM, the furnace can move too little or too much air, which affects comfort, efficiency, and the thermal load on the heat exchanger during a burn.

The most common causes are motor bearing wear that makes the speed unstable, a failing ECM control module that cannot hold the commanded RPM, or a dirty or unbalanced blower wheel that loads the motor unevenly; a marginal wiring connection between the control board and the motor can also produce it. Because the ECM's control electronics are bolted to the motor body, telling whether the winding or the module is at fault takes a technician's testing. T117_F is the troubleshooting-level counterpart of code A117_F, which is the persistent, alarm-level version of the same RPM mismatch. It should not be confused with code A061_F, where the motor cannot run at all rather than merely running at the wrong speed.

What You'll Notice

Common Causes

Cause Likelihood DIY?
Blower motor bearing wear causing speed variations Most common ✗ Call a pro →
ECM motor module failure Common ✗ Call a pro →
Dirty blower wheel causing motor strain Common ✗ Call a pro →

How This Is Diagnosed

Because T117_F involves the ECM blower motor, this is a technician diagnosis and the details here are informational. A technician confirms the board is commanding a valid speed and reading the RPM feedback, then works through the mechanical and electrical causes: they check whether the blower wheel is dirty or unbalanced enough to load the motor, feel and listen for worn bearings, inspect the harness and connectors between the control board and the motor for a marginal connection, and test the motor winding and the attached ECM control module separately. Because the electronics are integral to the ECM motor, isolating the winding from the module determines which part is replaced. Catching it at the troubleshooting stage matters because ongoing RPM instability can escalate to the alarm-level A117_F or a complete no-run failure.

When to Call a Professional

This code involves components that are not homeowner-serviceable, so have a licensed HVAC technician diagnose and repair it. Keep in mind:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Frequently Asked Questions

Can I keep running the furnace with T117_F showing?

The furnace may still run, but it is not moving the airflow it was designed for, which hurts efficiency and adds thermal stress to the heat exchanger. Because ongoing RPM instability can progress to the alarm-level A117_F or a complete motor failure, it is best to have it looked at rather than ignored.

How is T117_F different from A061_F?

T117_F means the blower motor is turning but at the wrong speed. A061_F means the motor cannot run at all and the furnace has latched a hard lockout. An RPM mismatch is a lesser failure than a motor that will not spin.

What is the difference between T117_F and A117_F?

T117_F is the troubleshooting-level RPM mismatch that the board observed without locking out. A117_F is the alarm-level, persistent version of the same fault, set when the RPM problem does not resolve on its own.

Could a dirty blower wheel really cause an RPM fault?

Yes. Debris built up on the blower wheel can unbalance it and load the motor unevenly, making it harder for the ECM to hold the commanded speed. A technician can clean and rebalance the wheel and confirm whether that resolves the mismatch.